Enucleated eye model for intraocular retinal prosthesis implantation
- PMID: 16898401
- DOI: 10.3928/15428877-20060701-17
Enucleated eye model for intraocular retinal prosthesis implantation
Abstract
An enucleated porcine eye model was developed to assess intraocular retinal prosthesis implantation surgery. The surgical technique consists of corneal and crystalline lens removal, keratoprosthesis replacement, and vitrectomy. To test the eye model, the scleral incision was increased to 5 mm and a 10-mm wide retinal prosthesis folded and inserted. One retinal tack was used to fix the prosthesis to the retina. A retinal prosthesis array was inserted without significant damage to the array and conformed to the curvature of the eye. Fundus photography and optical coherence tomography were performed at the end of surgery.
Similar articles
-
Surgical feasibility and biocompatibility of wide-field dual-array suprachoroidal-transretinal stimulation prosthesis in middle-sized animals.Graefes Arch Clin Exp Ophthalmol. 2016 Apr;254(4):661-73. doi: 10.1007/s00417-015-3104-1. Epub 2015 Jul 21. Graefes Arch Clin Exp Ophthalmol. 2016. PMID: 26194404
-
Development of surgical techniques for implantation of a wireless intraocular epiretinal retina implant in Göttingen minipigs.Graefes Arch Clin Exp Ophthalmol. 2012 Jan;250(1):51-9. doi: 10.1007/s00417-011-1756-z. Epub 2011 Aug 23. Graefes Arch Clin Exp Ophthalmol. 2012. PMID: 21861087
-
["Retinal implants"--replacement of retinal functions by technical implants: a feasible way to replace vision? The spokesman of the BMBF Research Committee "Retinal Implant"]].Ophthalmologe. 2001 Apr;98(4):353-6. doi: 10.1007/s003470170140. Ophthalmologe. 2001. PMID: 11374275 Review. German. No abstract available.
-
Long-term histological and electrophysiological results of an inactive epiretinal electrode array implantation in dogs.Invest Ophthalmol Vis Sci. 1999 Aug;40(9):2073-81. Invest Ophthalmol Vis Sci. 1999. PMID: 10440263
-
[Treatment with silicone oil in complicated retinal detachment. Anatomopathological test of 2 enucleated eyes].J Fr Ophtalmol. 1996;19(1):13-8. J Fr Ophtalmol. 1996. PMID: 8729837 Review. French.
Cited by
-
Full-field, conformal epiretinal electrode array using hydrogel and polymer hybrid technology.Sci Rep. 2023 Apr 28;13(1):6973. doi: 10.1038/s41598-023-32976-9. Sci Rep. 2023. PMID: 37117214 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources