Impact of sampling procedures on the results of breath analysis
- PMID: 21383448
- DOI: 10.1088/1752-7155/2/2/026007
Impact of sampling procedures on the results of breath analysis
Abstract
The impact of different sampling techniques on the results of breath analysis was to be assessed in this study. Alveolar, mixed expiratory and time-controlled samples were collected from ten volunteers and from eight lung cancer patients. Breath sampling was visually controlled by means of capnometry. PCO(2) and 13 VOCs were determined. Mixed expiratory sampling yielded 25% lower concentrations of CO(2) and blood-borne VOCs. Time-controlled sampling generated high variation of results. Ratios C(alv)/C(mixed) were >1.5 for CO(2), acetone and isoprene, and <1 for isopropanol, 2-butanone and hexanal. Acetonitrile, butane, dimethylsulfide, pentane, butanal, benzene and hexane showed 1.5 > C(alv)/C(mixed) > 1. The ratio C(alv)/C(mixed) of CO(2), acetone and isoprene was different in healthy volunteers and lung cancer patients. Alveolar samples showed the highest concentrations of endogenous and lowest concentration of exogenous substances. Sampling can impact results in breath analysis. Valuable information can be obtained from ratios of alveolar and mixed expired concentrations.
Similar articles
-
Molecular breath-gas analysis by online mass spectrometry in mechanically ventilated patients: a new software-based method of CO(2)-controlled alveolar gas monitoring.J Breath Res. 2008 Sep;2(3):037010. doi: 10.1088/1752-7155/2/3/037010. Epub 2008 Sep 8. J Breath Res. 2008. PMID: 21386171
-
A novel visually CO2 controlled alveolar breath sampling technique.Technol Health Care. 2006;14(6):499-506. Technol Health Care. 2006. PMID: 17148862
-
Diagnostic potential of breath analysis--focus on volatile organic compounds.Clin Chim Acta. 2004 Sep;347(1-2):25-39. doi: 10.1016/j.cccn.2004.04.023. Clin Chim Acta. 2004. PMID: 15313139 Review.
-
CO(2)-controlled sampling of alveolar gas in mechanically ventilated patients.J Appl Physiol (1985). 2001 Feb;90(2):486-92. doi: 10.1152/jappl.2001.90.2.486. J Appl Physiol (1985). 2001. PMID: 11160046
-
Comparison of three sampling and analytical methods for measuring m-xylene in expired air of exposed humans.Am Ind Hyg Assoc J. 1990 Mar;51(3):139-50. doi: 10.1080/15298669091369466. Am Ind Hyg Assoc J. 1990. PMID: 2327325
Cited by
-
An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone.Photoacoustics. 2024 Mar 21;38:100604. doi: 10.1016/j.pacs.2024.100604. eCollection 2024 Aug. Photoacoustics. 2024. PMID: 38559568 Free PMC article.
-
GC-MS-based metabolomics of volatile organic compounds in exhaled breath: applications in health and disease. A review.Front Mol Biosci. 2024 Jan 8;10:1295955. doi: 10.3389/fmolb.2023.1295955. eCollection 2023. Front Mol Biosci. 2024. PMID: 38298553 Free PMC article. Review.
-
Collision Enhanced Raman Scattering (CERS): An Ultra-High Efficient Raman Enhancement Technique for Hollow Core Photonic Crystal Fiber Based Raman Spectroscopy Gas Analyzer.Biosensors (Basel). 2023 Nov 9;13(11):979. doi: 10.3390/bios13110979. Biosensors (Basel). 2023. PMID: 37998154 Free PMC article.
-
Selectivity of Exhaled Breath Biomarkers of Lung Cancer in Relation to Cancer of Other Localizations.Int J Mol Sci. 2023 Aug 28;24(17):13350. doi: 10.3390/ijms241713350. Int J Mol Sci. 2023. PMID: 37686155 Free PMC article.
-
Advanced setup for safe breath sampling and patient monitoring under highly infectious conditions in the clinical environment.Sci Rep. 2022 Oct 26;12(1):17926. doi: 10.1038/s41598-022-22581-7. Sci Rep. 2022. PMID: 36289276 Free PMC article.
LinkOut - more resources
Full Text Sources