Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2011 Jun;55(2):302-10.
doi: 10.1637/9578-101510-ResNote.1.

Comparison of blood and feather pulp samples for the diagnosis of Marek's disease and for monitoring Marek's disease vaccination by real time-PCR

Affiliations

Comparison of blood and feather pulp samples for the diagnosis of Marek's disease and for monitoring Marek's disease vaccination by real time-PCR

Aneg L Cortes et al. Avian Dis. 2011 Jun.

Abstract

Comparison of blood and feather pulp (FP) samples for the diagnosis of Marek's disease (MD) and for monitoring Marek's diseases vaccination in chickens (serotypes 2 and 3 vaccines) by real time-PCR was evaluated. For diagnosis of MD, quantification of serotype 1 Marek's disease virus (MDV) DNA load was evaluated in 21 chickens suffering from MD. For each chicken, samples of blood and FP were collected and MDV DNA load was quantified. Solid tumors are the sample of choice for MD diagnosis by real time-PCR and, hence, 14 solid tumors were included in the study as positive controls. Load of MDV DNA in FP was equivalent to that detected in solid tumors (threshold cycle [Ct] ratio above 1.7). MDV DNA load in blood samples was lower than in solid tumors and FP samples. Nonetheless, there was a statistically significant correlation of the results obtained from FP and blood (r = 0.92). Results of the Pearson correlation test showed that Ct ratio values of 1.7 in FP correspond to Ct ratio values of 1.2 in peripheral blood. For monitoring vaccines, serotypes 2 and 3 MDV DNA load was evaluated in blood and FP samples of vaccinated chickens. Serotype 2 MDV DNA load was evaluated in samples of blood and FP from 34 chickens vaccinated with SB-1 strain. Serotype 3 MDV DNA load was evaluated in blood and FP samples from 53 chickens vaccinated with HVT strain. For both serotypes, frequency of positive samples and load of vaccine DNA was higher in FP than in blood samples. There was not a statistically significant correlation between the load of SB-1 DNA (r = 0.17) or HVT DNA (r = -0.04) in FP and blood. Our results show that the load of serotypes 1, 2, and 3 DNA is higher in FP than in blood. Diagnosis of MD could be done using both FP and blood samples. Monitoring of MD vaccination by real time-PCR required the use of FP samples. There were a high percentage of false negative samples when using blood to detect serotypes 2 and 3 MDV by real time-PCR.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources

-