Keeping babies warm: a non-inferiority trial of a conductive thermal mattress
- PMID: 25791056
- DOI: 10.1136/archdischild-2014-306269
Keeping babies warm: a non-inferiority trial of a conductive thermal mattress
Abstract
Background: External thermal support is critical for preterm or ill infants due to altered thermoregulation. Incubators are the gold standard for long-term support and have been adopted successfully in many countries. Alternatives such as radiant warmers, blankets and others are often used as standard of care (SoC) in resource-limited settings when infants are otherwise not in Kangaroo Mother Care (KMC).
Methods: In this pilot study, we evaluate the feasibility of a conductive thermal mattress (CTM) using phase change materials as a low-cost warmer. We conducted a prospective multicentre open-label randomised controlled trial to determine non-inferiority of this CTM to SoC warming practices in low birthweight infants. The primary outcome was maintenance of axillary temperature.
Results: We equally randomised 160 infants to CTM or SoC. The latter cohort continued to receive warmth by radiant warmers (n=48), blankets (n=18), warmed cradles (n=7) or KMC (n=7) before, during and subsequent to the study. CTM was deemed non-inferior since warmed babies had higher axillary temperature compared with SoC (mean increase 0.11±0.03°C SEM; p<0.001). Post hoc comparison to radiant warmers alone showed that CTM led to a higher axillary temperature (mean increase by 0.14±0.03°C SEM; p<0.001).
Conclusions: Short-term use of CTM compared with radiant warmers and other modes of warming is non-inferior to SoC and efficacious in maintaining body temperature. No adverse effects were reported. An extended multinational trial, preferably one that demonstrates longer-term thermoregulation, is warranted.
Trial registration number: Clinical Trials Registry of India (CTRI/2010/091/002916 and CTRI/2011/04/001696).
Keywords: Intensive Care; Neonatology; Technology; Temp Regulation.
Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Similar articles
-
Disposable low-cost cardboard incubator for thermoregulation of stable preterm infant - a randomized controlled non-inferiority trial.EClinicalMedicine. 2020 Dec 7;31:100664. doi: 10.1016/j.eclinm.2020.100664. eCollection 2021 Jan. EClinicalMedicine. 2020. PMID: 33554076 Free PMC article.
-
Randomized controlled trial of vinyl bags versus thermal mattress to prevent hypothermia in extremely low-gestational-age infants.Am J Perinatol. 2013 Apr;30(4):317-22. doi: 10.1055/s-0032-1324700. Epub 2012 Aug 14. Am J Perinatol. 2013. PMID: 22893555 Clinical Trial.
-
Radiant warmers versus incubators for regulating body temperature in newborn infants.Cochrane Database Syst Rev. 2003;(4):CD000435. doi: 10.1002/14651858.CD000435. Cochrane Database Syst Rev. 2003. PMID: 14583922 Review.
-
Radiant warmers versus incubators for regulating body temperature in newborn infants.Cochrane Database Syst Rev. 2002;(2):CD000435. doi: 10.1002/14651858.CD000435. Cochrane Database Syst Rev. 2002. Update in: Cochrane Database Syst Rev. 2003;(4):CD000435. doi: 10.1002/14651858.CD000435. PMID: 12076397 Updated. Review.
-
Optimal thermal management for low birth weight infants nursed under high-powered radiant warmers.Pediatrics. 1987 Jan;79(1):47-54. Pediatrics. 1987. PMID: 3797170 Clinical Trial.
Cited by
-
Conductive thermal mattress versus routine care to reduce neonatal hypothermia during transport among low-birthweight neonates: An experimental study with historical controls.Med J Armed Forces India. 2022 Sep;78(Suppl 1):S49-S54. doi: 10.1016/j.mjafi.2020.10.022. Epub 2021 Jan 6. Med J Armed Forces India. 2022. PMID: 36147431 Free PMC article.
-
Disposable low-cost cardboard incubator for thermoregulation of stable preterm infant - a randomized controlled non-inferiority trial.EClinicalMedicine. 2020 Dec 7;31:100664. doi: 10.1016/j.eclinm.2020.100664. eCollection 2021 Jan. EClinicalMedicine. 2020. PMID: 33554076 Free PMC article.
-
Performance of a Nonelectric Infant Warmer in Rwandan Health Centers.Glob Pediatr Health. 2019 Oct 24;6:2333794X19884820. doi: 10.1177/2333794X19884820. eCollection 2019. Glob Pediatr Health. 2019. PMID: 31696147 Free PMC article.
-
A low cost, re-usable electricity-free infant warmer: evaluation of safety, effectiveness and feasibiliy.Public Health Action. 2018 Dec 21;8(4):211-217. doi: 10.5588/pha.18.0031. Public Health Action. 2018. PMID: 30775282 Free PMC article.
-
Kangaroo mother care for clinically unstable neonates weighing ≤2000 g: Is it feasible at a hospital in Uganda?J Glob Health. 2018 Jun;8(1):010701. doi: 10.7189/jogh.08.010701. J Glob Health. 2018. PMID: 29497509 Free PMC article.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources