An analysis of observer-rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years

Affiliations
Clinical Trial

An analysis of observer-rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years

Duane R Geruschat et al. Clin Exp Optom. 2016 May.

Abstract

Objective: The purpose of this analysis was to compare observer-rated tasks in patients implanted with the Argus II Retinal Prosthesis System, when the device is ON versus OFF.

Methods: The Functional Low-Vision Observer Rated Assessment (FLORA) instrument was administered to 26 blind patients implanted with the Argus II Retinal Prosthesis System at a mean follow-up of 36 months. FLORA is a multi-component instrument that consists in part of observer-rated assessment of 35 tasks completed with the device ON versus OFF. The ease with which a patient completes a task is scored using a four-point scale, ranging from easy (score of 1) to impossible (score of 4). The tasks are evaluated individually and organised into four discrete domains, including 'Visual orientation', 'Visual mobility', 'Daily life and 'Interaction with others'.

Results: Twenty-six patients completed each of the 35 tasks. Overall, 24 out of 35 tasks (69 per cent) were statistically significantly easier to achieve with the device ON versus OFF. In each of the four domains, patients' performances were significantly better (p < 0.05) with the device ON versus OFF, ranging from 19 to 38 per cent improvement.

Conclusion: Patients with an Argus II Retinal Prosthesis implanted for 18 to 44 months (mean 36 months), demonstrated significantly improved completion of vision-related tasks with the device ON versus OFF.

Keywords: Argus II; FLORA; functional vision; retinal prosthesis; retinitis pigmentosa.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Dagnelie G. Retinal implants: Emergence of a multidisciplinary field. Curr Opin Neurol 2012; 25: 67–75. - PMC - PubMed
    1. Humayun MS, Dorn JD, da Cruz L, Dagnelie G, Sahel JA, Stanga PE, Cideciyan AV et al. Interim results from the international trial of Second Sight's visual prosthesis. Ophthalmology 2012; 119: 779–788. - PMC - PubMed
    1. Ho AC, Humayun MS, Dorn JD, da Cruz L, Dagnelie G, Handa J, et al. Long‐term results from an epiretinal prosthesis to restore sight to the blind. Ophthalmology 2015; 122: 1547–1554. - PMC - PubMed
    1. Scheiman M. Understanding and Managing Vision Deficits: A Guide for Occupational Therapists. Thorofare, New Jersey, USA: Slack, Inc, 2011.
    1. Stelmack JA, Stelmack, TR , Massof, RW . Measuring low‐vision rehabilitation outcomes with the NEI VFQ‐25. Invest Ophthalmol Vis Sci 2002; 43: 2859–2868. - PubMed

Publication types

-