Interpreting lung function data using 80% predicted and fixed thresholds misclassifies more than 20% of patients
- PMID: 20522571
- DOI: 10.1378/chest.10-0189
Interpreting lung function data using 80% predicted and fixed thresholds misclassifies more than 20% of patients
Erratum in
- Chest. 2011 Mar;139(3):733
Abstract
Background: Differences in COPD classification have been shown in population data sets when using fifth percentiles as the lower limit of normal (LLN) vs the current GOLD (Global Initiative for Chronic Obstructive Lung Disease) guidelines of FEV(1)/FVC < 0.70 for detecting airway obstruction and an FEV(1) of 80% predicted for detecting and classifying the severity of COPD (GOLD/PP). Many lung function laboratories use 80% predicted to determine whether results are abnormal. Misclassification of the full range of lung diseases in large patient groups when using GOLD/PP criteria instead of the LLN has not been explored previously.
Methods: We determined the discrepancy rates in pulmonary function test interpretation between the GOLD/PP and LLN methods on prebronchodilator lung function results from a large number of adult patients from the United Kingdom, New Zealand, and the United States.
Results: In 11,413 patients, the GOLD/PP method misclassified 24%. Ten percent of patients who had normal lung function were falsely classified with a disease category, and 7% of patients were falsely attributed with emphysema. The GOLD/PP method gave false-positive classifications for airflow obstruction and restrictive defects to significantly more men (P < .01) and older patients (P < .0001) and also missed airflow obstruction and restrictive defects in younger patients (P < .0001).
Conclusions: Using lung function tests on their own with 80% predicted and fixed cut points to determine whether a test is abnormal could misdiagnose > 20% of patients referred for pulmonary function tests. The GOLD/PP method introduces clinically important biases in assessing disease status that could affect allocation to treatment groups. This misclassification is avoided by using the LLN based on the fifth-percentile values.
Comment in
-
Lower limit of normal is better than 70% or 80%.Chest. 2011 Jan;139(1):6-8. doi: 10.1378/chest.10-1117. Chest. 2011. PMID: 21208872 No abstract available.
Similar articles
-
Interpreting lung function data using 80% predicted and fixed thresholds identifies patients at increased risk of mortality.Chest. 2012 Jan;141(1):73-80. doi: 10.1378/chest.11-0797. Epub 2011 Jun 9. Chest. 2012. PMID: 21659434
-
Comparison of the lower confidence limit to the fixed-percentage method for assessing airway obstruction in routine clinical practice.Respir Care. 2011 Nov;56(11):1778-84. doi: 10.4187/respcare.01160. Epub 2011 May 20. Respir Care. 2011. PMID: 21605485
-
Lower limit of normal or FEV1/FVC < 0.70 in diagnosing COPD: an evidence-based review.Respir Med. 2011 Jun;105(6):907-15. doi: 10.1016/j.rmed.2011.01.008. Epub 2011 Feb 5. Respir Med. 2011. PMID: 21295958 Review.
-
Using the lower limit of normal for the FEV1/FVC ratio reduces the misclassification of airway obstruction.Thorax. 2008 Dec;63(12):1046-51. doi: 10.1136/thx.2008.098483. Epub 2008 Sep 11. Thorax. 2008. PMID: 18786983
-
What defines abnormal lung function in older adults with chronic obstructive pulmonary disease?Drugs Aging. 2008;25(9):717-28. doi: 10.2165/00002512-200825090-00001. Drugs Aging. 2008. PMID: 18729545 Review.
Cited by
-
Functional gas exchange measures on 129Xe MRI and spectroscopy are associated with age, sex, and BMI in healthy subjects.Front Med (Lausanne). 2024 Apr 8;11:1342499. doi: 10.3389/fmed.2024.1342499. eCollection 2024. Front Med (Lausanne). 2024. PMID: 38651062 Free PMC article.
-
Pulmonary function as a continuum of risk: critical care utilization and survival after allogeneic hematopoietic stem cell transplantation - a multicenter cohort study.Bone Marrow Transplant. 2024 Jul;59(7):942-949. doi: 10.1038/s41409-024-02265-8. Epub 2024 Mar 16. Bone Marrow Transplant. 2024. PMID: 38493276
-
Spirometric Interpretation and Clinical Relevance According to Different Reference Equations.J Korean Med Sci. 2024 Jan 29;39(4):e20. doi: 10.3346/jkms.2024.39.e20. J Korean Med Sci. 2024. PMID: 38288534 Free PMC article.
-
Validity of the Espiro Mobile Application in the Interpretation of Spirometric Patterns: An App Accuracy Study.Diagnostics (Basel). 2023 Dec 22;14(1):29. doi: 10.3390/diagnostics14010029. Diagnostics (Basel). 2023. PMID: 38201338 Free PMC article.
-
GOLD 2024: a brief overview of key changes.J Bras Pneumol. 2023 Dec 22;49(6):e20230369. doi: 10.36416/1806-3756/e20230369. J Bras Pneumol. 2023. PMID: 38126685 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous