Comparative Study
. 2011 Jan;139(1):52-9.
doi: 10.1378/chest.10-0189. Epub 2010 Jun 3.

Interpreting lung function data using 80% predicted and fixed thresholds misclassifies more than 20% of patients

Affiliations
Comparative Study

Interpreting lung function data using 80% predicted and fixed thresholds misclassifies more than 20% of patients

Martin R Miller et al. Chest. 2011 Jan.

Erratum in

  • Chest. 2011 Mar;139(3):733

Abstract

Background: Differences in COPD classification have been shown in population data sets when using fifth percentiles as the lower limit of normal (LLN) vs the current GOLD (Global Initiative for Chronic Obstructive Lung Disease) guidelines of FEV(1)/FVC < 0.70 for detecting airway obstruction and an FEV(1) of 80% predicted for detecting and classifying the severity of COPD (GOLD/PP). Many lung function laboratories use 80% predicted to determine whether results are abnormal. Misclassification of the full range of lung diseases in large patient groups when using GOLD/PP criteria instead of the LLN has not been explored previously.

Methods: We determined the discrepancy rates in pulmonary function test interpretation between the GOLD/PP and LLN methods on prebronchodilator lung function results from a large number of adult patients from the United Kingdom, New Zealand, and the United States.

Results: In 11,413 patients, the GOLD/PP method misclassified 24%. Ten percent of patients who had normal lung function were falsely classified with a disease category, and 7% of patients were falsely attributed with emphysema. The GOLD/PP method gave false-positive classifications for airflow obstruction and restrictive defects to significantly more men (P < .01) and older patients (P < .0001) and also missed airflow obstruction and restrictive defects in younger patients (P < .0001).

Conclusions: Using lung function tests on their own with 80% predicted and fixed cut points to determine whether a test is abnormal could misdiagnose > 20% of patients referred for pulmonary function tests. The GOLD/PP method introduces clinically important biases in assessing disease status that could affect allocation to treatment groups. This misclassification is avoided by using the LLN based on the fifth-percentile values.

PubMed Disclaimer

Comment in

Similar articles

Cited by