Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Nov 25;55(12):8458-66.
doi: 10.1167/iovs.14-14732.

Developing an instrumental activities of daily living tool as part of the low vision assessment of daily activities protocol

Affiliations

Developing an instrumental activities of daily living tool as part of the low vision assessment of daily activities protocol

Robert P Finger et al. Invest Ophthalmol Vis Sci. .

Abstract

Purpose: To determine the validity, reliability, and measurement characteristics using factor and Rasch analysis of the Very Low Vision Instrumental Activities of Daily Living (IADL-VLV) in persons with severe vision loss.

Methods: From an initial pool of 296 tasks, 25 were shortlisted after conducting a Delphi survey with persons designated legally blind. Using further input from occupational therapy and low-vision professionals, 11 activities were chosen to be pilot tested. Forty legally blind participants (better eye visual acuity < 20/200) underwent clinical assessments and functional tests as well as the 53 IADL tasks related to the 11 activities. The task pool was refined and condensed using factor and Rasch analysis.

Results: Based on iterative principal component analyses, tasks were grouped together into the following domains: reading signs/information access, signature placement, clothes sorting, shelf search, gesture recognition, clock reading, and table search. A final selection of 23 tasks yielded satisfactory measurement characteristics, differentiated between at least four different levels of IADL performance (person separation of 3.8), and had adequate task difficulty for the tested sample (person mean -0.61). In multivariate analyses, only visual acuity (VA) and percent of remaining visual field (VF) were associated with IADL performance.

Conclusions: Using a large item pool, participant, and expert input, as well as factor and Rasch analysis, we designed a valid and reliable assessment to measure vision-related IADL performance in persons with severe vision loss. This assessment tool can be used in clinical sight restoration trials.

Keywords: Activities of Daily Living; instrument development; psychometric measurement; retinitis pigmentosa; visual impairment.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources

-