Mobility and low contrast trip hazard avoidance using augmented depth
- PMID: 25427135
- DOI: 10.1088/1741-2560/12/1/016003
Mobility and low contrast trip hazard avoidance using augmented depth
Abstract
Objective: We evaluated a novel visual representation for current and near-term prosthetic vision. Augmented depth emphasizes ground obstacles and floor-wall boundaries in a depth-based visual representation. This is achieved by artificially increasing contrast between obstacles and the ground surface via a novel ground plane extraction algorithm specifically designed to preserve low-contrast ground-surface boundaries.
Approach: The effectiveness of augmented depth was examined in human mobility trials compared against standard intensity-based (Intensity), depth-based (Depth) and random (Random) visual representations. Eight participants with normal vision used simulated prosthetic vision with 20 phosphenes and eight perceivable brightness levels to traverse a course with randomly placed small and low-contrast obstacles on the ground.
Main results: The number of collisions was significantly reduced using augmented depth, compared with intensity, depth and random representations (48%, 44% and 72% less collisions, respectively).
Significance: These results indicate that augmented depth may enable safe mobility in the presence of low-contrast obstacles with current and near-term implants. This is the first demonstration that an augmentation of the scene ensuring key objects are visible may provide better outcomes for prosthetic vision.
Similar articles
-
Assistive peripheral phosphene arrays deliver advantages in obstacle avoidance in simulated end-stage retinitis pigmentosa: a virtual-reality study.J Neural Eng. 2016 Apr;13(2):026022. doi: 10.1088/1741-2560/13/2/026022. Epub 2016 Feb 23. J Neural Eng. 2016. PMID: 26902525
-
Improved visual performance in letter perception through edge orientation encoding in a retinal prosthesis simulation.J Neural Eng. 2014 Dec;11(6):066002. doi: 10.1088/1741-2560/11/6/066002. Epub 2014 Oct 13. J Neural Eng. 2014. PMID: 25307496
-
Substituting depth for intensity and real-time phosphene rendering: visual navigation under low vision conditions.Annu Int Conf IEEE Eng Med Biol Soc. 2011;2011:8017-20. doi: 10.1109/IEMBS.2011.6091977. Annu Int Conf IEEE Eng Med Biol Soc. 2011. PMID: 22256201
-
Simulating prosthetic vision: I. Visual models of phosphenes.Vision Res. 2009 Jun;49(12):1493-506. doi: 10.1016/j.visres.2009.02.003. Vision Res. 2009. PMID: 19504749 Review.
-
Rehabilitation regimes based upon psychophysical studies of prosthetic vision.J Neural Eng. 2009 Jun;6(3):035009. doi: 10.1088/1741-2560/6/3/035009. Epub 2009 May 20. J Neural Eng. 2009. PMID: 19458400 Review.
Cited by
-
Great expectations: Aligning visual prosthetic development with implantee needs.medRxiv [Preprint]. 2024 Mar 14:2024.03.12.24304186. doi: 10.1101/2024.03.12.24304186. medRxiv. 2024. PMID: 38559196 Free PMC article. Preprint.
-
A systematic review of extended reality (XR) for understanding and augmenting vision loss.J Vis. 2023 May 2;23(5):5. doi: 10.1167/jov.23.5.5. J Vis. 2023. PMID: 37140911 Free PMC article.
-
Towards aSmart Bionic Eye: AI-powered artificial vision for the treatment of incurable blindness.J Neural Eng. 2022 Dec 7;19(6):10.1088/1741-2552/aca69d. doi: 10.1088/1741-2552/aca69d. J Neural Eng. 2022. PMID: 36541463 Free PMC article.
-
Real-world indoor mobility with simulated prosthetic vision: The benefits and feasibility of contour-based scene simplification at different phosphene resolutions.J Vis. 2022 Feb 1;22(2):1. doi: 10.1167/jov.22.2.1. J Vis. 2022. PMID: 35103758 Free PMC article.
-