Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1986 Feb 15;57(6):450-8.
doi: 10.1016/0002-9149(86)90771-x.

Echocardiographic assessment of left ventricular hypertrophy: comparison to necropsy findings

Comparative Study

Echocardiographic assessment of left ventricular hypertrophy: comparison to necropsy findings

R B Devereux et al. Am J Cardiol. .

Abstract

To determine the accuracy of echocardiographic left ventricular (LV) dimension and mass measurements for detection and quantification of LV hypertrophy, results of blindly read antemortem echocardiograms were compared with LV mass measurements made at necropsy in 55 patients. LV mass was calculated using M-mode LV measurements by Penn and American Society of Echocardiography (ASE) conventions and cube function and volume correction formulas in 52 patients. Penn-cube LV mass correlated closely with necropsy LV mass (r = 0.92, p less than 0.001) and overestimated it by only 6%; sensitivity in 18 patients with LV hypertrophy (necropsy LV mass more than 215 g) was 100% (18 of 18 patients) and specificity was 86% (29 of 34 patients). ASE-cube LV mass correlated similarly to necropsy LV mass (r = 0.90, p less than 0.001), but systematically overestimated it (by a mean of 25%); the overestimation could be corrected by the equation: LV mass = 0.80 (ASE-cube LV mass) + 0.6 g. Use of ASE measurements in the volume correction formula systematically underestimated necropsy LV mass (by a mean of 30%). In a subset of 9 patients, 3 of whom had technically inadequate M-mode echocardiograms, 2-dimensional echocardiographic (echo) LV mass by 2 methods was also significantly related to necropsy LV mass (r = 0.68, p less than 0.05 and r = 0.82, p less than 0.01). Among other indexes of LV anatomy, only measurement of myocardial cross-sectional area was acceptably accurate for quantitation of LV mass (r = 0.80, p less than 0.001) or diagnosis of LV hypertrophy (sensitivity = 72%, specificity = 94%).(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources

-