A dual-respiration chamber system with automated calibration
- PMID: 9390982
- DOI: 10.1152/jappl.1997.83.6.2064
A dual-respiration chamber system with automated calibration
Abstract
This study characterizes respiration chambers with fully automated calibration. The system consists of two 14-m3 pull-type chambers. Care was taken to provide a friendly environment for the subjects, with the possibility of social contact during the experiment. Gas analysis was automated to correct for analyzer drift and barometric pressure variations and to provide ease of use. Methods used for checking the system's performance are described. The gas-analysis repeatability was within 0.002%. Results of alcohol combustion (50-350 ml/min CO2) show an accuracy of 0.5 +/- 2.0 (SD) % for O2 consumption and -0.3 +/- 1.6% for CO2 production for 2- to 24-h experiments. It is concluded that response time is not the main factor with respect to the smallest practical measurement interval (duration); volume, mixing, gas-analysis accuracy, and levels of O2 consumption and CO2 production are at least equally important. The smallest practical interval was 15-25 min, as also found with most chamber systems described in the literature. We chose to standardize 0.5 h as the minimum measurement interval.
Similar articles
-
New metabolic lung simulator: development, description, and validation.J Clin Monit Comput. 2007 Apr;21(2):71-82. doi: 10.1007/s10877-006-9058-4. Epub 2007 Mar 1. J Clin Monit Comput. 2007. PMID: 17333487
-
Some mathematical and technical issues in the measurement and interpretation of open-circuit indirect calorimetry in small animals.Int J Obes (Lond). 2006 Sep;30(9):1322-31. doi: 10.1038/sj.ijo.0803280. Epub 2006 Jun 27. Int J Obes (Lond). 2006. PMID: 16801931 Review.
-
Validity and reliability of a new portable telemetric calorimeter designed to measure oxygen consumption and carbon dioxide production.Diabetes Nutr Metab. 2001 Oct;14(5):268-76. Diabetes Nutr Metab. 2001. PMID: 11806467
-
Effect of accumulation of CO2 on the survival of immature pigs in a confined atmosphere. A: Gas exchange.J Basic Clin Physiol Pharmacol. 1995;6(1):1-18. doi: 10.1515/jbcpp.1995.6.1.1. J Basic Clin Physiol Pharmacol. 1995. PMID: 8562575
-
An open circuit respiration unit for calorimetric studies with small animals.Arch Tierernahr. 1985 Dec;35(12):825-33. doi: 10.1080/17450398509421044. Arch Tierernahr. 1985. PMID: 2937387
Cited by
-
Comparison of energy expenditure measurements by a new basic respiratory room vs. classical ventilated hood.Nutr J. 2023 Dec 20;22(1):72. doi: 10.1186/s12937-023-00903-3. Nutr J. 2023. PMID: 38114986 Free PMC article.
-
Changes in 24-h energy expenditure, substrate oxidation, and body composition following resistance exercise and a high protein diet via whey protein supplementation in healthy older men.Physiol Rep. 2022 Jun;10(11):e15268. doi: 10.14814/phy2.15268. Physiol Rep. 2022. PMID: 37815091 Free PMC article. Clinical Trial.
-
The Berlin-Buch respiration chamber for energy expenditure measurements.Eur J Appl Physiol. 2023 Jun;123(6):1359-1368. doi: 10.1007/s00421-023-05164-w. Epub 2023 Feb 27. Eur J Appl Physiol. 2023. PMID: 36849666 Free PMC article.
-
Replacing Foods with a High-Glycemic Index and High in Saturated Fat by Alternatives with a Low Glycemic Index and Low Saturated Fat Reduces Hepatic Fat, Even in Isocaloric and Macronutrient Matched Conditions.Nutrients. 2023 Feb 1;15(3):735. doi: 10.3390/nu15030735. Nutrients. 2023. PMID: 36771441 Free PMC article. Clinical Trial.
-
The cost of chewing: The energetics and evolutionary significance of mastication in humans.Sci Adv. 2022 Aug 19;8(33):eabn8351. doi: 10.1126/sciadv.abn8351. Epub 2022 Aug 17. Sci Adv. 2022. PMID: 35977013 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources