Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2003 Dec;97(6):1795-1799.
doi: 10.1213/01.ANE.0000086733.92150.47.

The effect of right versus left lateral decubitus positions on induction of spinal anesthesia for cesarean delivery

Affiliations
Clinical Trial

The effect of right versus left lateral decubitus positions on induction of spinal anesthesia for cesarean delivery

Alice C S Law et al. Anesth Analg. 2003 Dec.

Abstract

Induction of spinal anesthesia for cesarean delivery in the left lateral (LL) decubitus position combined with intraoperative left uterine displacement may result in pooling of local anesthetic onto one side of the body. We studied the effect of the right lateral (RL) and LL decubitus positions during placement of spinal anesthesia on the intrathecal spread of 0.5% hyperbaric bupivacaine plus fentanyl in 60 term parturients. Though all parturients acquired a loss of cold sensation at T4 15 min after intrathecal injection, more parturients in the LL group than in the RL group did so at 5 min (P < 0.05). The maximum levels of sensory blockades, amounts of fluid, vasopressor, and supplementary analgesia used, and the incidence of postoperative complications were similar. We conclude that the two positions can be used equally well when hyperbaric bupivacaine and fentanyl are used in cesarean delivery under spinal anesthesia.

Implications: We conducted a double-blinded randomized trial comparing the spread of spinal anesthesia placed with a parturient in either the right or left lateral position. There was a faster onset in the left lateral group; however, the maximum block heights and the time taken to achieve them were similar in both groups.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Norris MC. Patient variables and the subarachnoid spread of hyperbaric bupivacaine in the term parturient. Anesthesiology 1990; 72: 478–82.
    1. Vercauteren MP, Coppejans HC, Hoffmann VL, et al. Small-dose hyperbaric versus plain bupivacaine during spinal anesthesia for cesarean section. Anesth Analg 1998; 86: 989–93.
    1. Sarvela PJ, Halonen PM, Korttila KT. Comparison of 9 mg of intrathecal plain and hyperbaric bupivacaine both with fentanyl for cesarean delivery. Anesth Analg 1999; 89: 1257–62.
    1. Chung CJ, Bae SH, Chae KY, Chin YJ. Spinal anaesthesia with 0.25% hyperbaric bupivacaine for Caesarean section: effects of volume. Br J Anaesth 1996; 77: 145–9.
    1. Russell IF. Effect of posture during the induction of subarachnoid analgesia for Caesarean section. Br J Anaesth 1987; 59: 342–6.

Publication types

LinkOut - more resources

-