The effect of right versus left lateral decubitus positions on induction of spinal anesthesia for cesarean delivery
- PMID: 14633562
- DOI: 10.1213/01.ANE.0000086733.92150.47
The effect of right versus left lateral decubitus positions on induction of spinal anesthesia for cesarean delivery
Abstract
Induction of spinal anesthesia for cesarean delivery in the left lateral (LL) decubitus position combined with intraoperative left uterine displacement may result in pooling of local anesthetic onto one side of the body. We studied the effect of the right lateral (RL) and LL decubitus positions during placement of spinal anesthesia on the intrathecal spread of 0.5% hyperbaric bupivacaine plus fentanyl in 60 term parturients. Though all parturients acquired a loss of cold sensation at T4 15 min after intrathecal injection, more parturients in the LL group than in the RL group did so at 5 min (P < 0.05). The maximum levels of sensory blockades, amounts of fluid, vasopressor, and supplementary analgesia used, and the incidence of postoperative complications were similar. We conclude that the two positions can be used equally well when hyperbaric bupivacaine and fentanyl are used in cesarean delivery under spinal anesthesia.
Implications: We conducted a double-blinded randomized trial comparing the spread of spinal anesthesia placed with a parturient in either the right or left lateral position. There was a faster onset in the left lateral group; however, the maximum block heights and the time taken to achieve them were similar in both groups.
Similar articles
-
Does the baricity of bupivacaine influence intrathecal spread in the prolonged sitting position before elective cesarean delivery? A prospective randomized controlled study.Anesth Analg. 2011 Oct;113(4):811-7. doi: 10.1213/ANE.0b013e3182288bf2. Epub 2011 Sep 2. Anesth Analg. 2011. PMID: 21890887 Clinical Trial.
-
The effect of posture and baricity on the spread of intrathecal bupivacaine for elective cesarean delivery.Anesth Analg. 2005 Apr;100(4):1159-1165. doi: 10.1213/01.ANE.0000149548.88029.A2. Anesth Analg. 2005. PMID: 15781538 Clinical Trial.
-
[The effect of intrathecal fentanyl added to hyperbaric bupivacaine for caesarean section].Masui. 2003 Apr;52(4):378-82. Masui. 2003. PMID: 12728487 Clinical Trial. Japanese.
-
Low-dose bupivacaine-fentanyl spinal anesthesia for cesarean delivery.Reg Anesth Pain Med. 2000 May-Jun;25(3):235-9. Reg Anesth Pain Med. 2000. PMID: 10834776 Clinical Trial.
-
Comparison of 9 mg of intrathecal plain and hyperbaric bupivacaine both with fentanyl for cesarean delivery.Anesth Analg. 1999 Nov;89(5):1257-62. Anesth Analg. 1999. PMID: 10553846 Clinical Trial.
Cited by
-
Techniques for preventing hypotension during spinal anaesthesia for caesarean section.Cochrane Database Syst Rev. 2020 Jul 1;7(7):CD002251. doi: 10.1002/14651858.CD002251.pub4. Cochrane Database Syst Rev. 2020. PMID: 32619039 Free PMC article.
-
Techniques for preventing hypotension during spinal anaesthesia for caesarean section.Cochrane Database Syst Rev. 2017 Aug 4;8(8):CD002251. doi: 10.1002/14651858.CD002251.pub3. Cochrane Database Syst Rev. 2017. Update in: Cochrane Database Syst Rev. 2020 Jul 1;7:CD002251. doi: 10.1002/14651858.CD002251.pub4. PMID: 28976555 Free PMC article. Updated. Review.
-
Comparison of Maternal and Neonatal Effects of Combined Spinal Epidural Anaesthesia in Either the Sitting or Lateral Position During Elective Cesarean Section.Turk J Anaesthesiol Reanim. 2014 Feb;42(1):23-32. doi: 10.5152/TJAR.2013.55. Epub 2013 Aug 29. Turk J Anaesthesiol Reanim. 2014. PMID: 27366384 Free PMC article.
-
Hypotension after spinal anesthesia for cesarean section: identification of risk factors using an anesthesia information management system.J Clin Monit Comput. 2009 Apr;23(2):85-92. doi: 10.1007/s10877-009-9168-x. Epub 2009 Mar 10. J Clin Monit Comput. 2009. PMID: 19277879
References
-
- Norris MC. Patient variables and the subarachnoid spread of hyperbaric bupivacaine in the term parturient. Anesthesiology 1990; 72: 478–82.
-
- Vercauteren MP, Coppejans HC, Hoffmann VL, et al. Small-dose hyperbaric versus plain bupivacaine during spinal anesthesia for cesarean section. Anesth Analg 1998; 86: 989–93.
-
- Sarvela PJ, Halonen PM, Korttila KT. Comparison of 9 mg of intrathecal plain and hyperbaric bupivacaine both with fentanyl for cesarean delivery. Anesth Analg 1999; 89: 1257–62.
-
- Chung CJ, Bae SH, Chae KY, Chin YJ. Spinal anaesthesia with 0.25% hyperbaric bupivacaine for Caesarean section: effects of volume. Br J Anaesth 1996; 77: 145–9.
-
- Russell IF. Effect of posture during the induction of subarachnoid analgesia for Caesarean section. Br J Anaesth 1987; 59: 342–6.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical