Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Feb;16(1):27-34.
doi: 10.1111/j.1600-0838.2004.00424.x.

Predictive validity of ventilatory and lactate thresholds for cycling time trial performance

Affiliations

Predictive validity of ventilatory and lactate thresholds for cycling time trial performance

Markus Amann et al. Scand J Med Sci Sports. 2006 Feb.

Abstract

Purpose: To determine which laboratory measurement best predicts 40 km cycling time-trial (TT) performance.

Methods: Fifteen male cyclists performed lactate-threshold (LT), ventilatory-threshold (VT), 5 km and 40 km TT. Key variables of interest were Watts at thresholds. For VT determination we used: breakpoint of ventilatory equivalent of oxygen (VE/VO2); breakpoint of ventilatory equivalent of carbon dioxide (VE/VCO2); V-slope; respiratory exchange ratio (RER)=1 and 0.95. For LT we used Stegmann's individual anaerobic threshold; the stage preceding the second 0.5 mmol L(-1) increase (Baldari); 4 mmol L(-1); 1 mmol L(-1) increase in 3 min; the stage preceding the first 1 mmol L(-1) increase as criterion methods (<1 mmol). Analyses also included peak power during the incremental threshold tests (MaxVT(watts), MaxLT(watts)) and 5 km performance (5K(avgwatts)).

Results: Regression analyses between VT variables and 40K(avgwatts) were significant for V-slope (r2=0.63), VE/VO2 (r2=0.64), RER(0.95) (r2=0.53), RER1 (r2=0.57), and MaxVT(watts) (r2=0.65). Regressions between LT variables and 40K(avgwatts) were significant for Baldari (r2=0.52), 4 mmol L(-1) (r2=0.36), <1 mmol (r2=0.35), Keul (r2=0.34), and MaxLT(watts) (r2=0.51). Regressions between 5K variables and 40K(avgwatts) were significant for 5K(avgwatts) (r2=0.58). Paired t-tests between these variables and the 40K(avgwatts) indicated that absolute power outputs at VE/VO2 (P=0.33), RER(0.95) (P=0.93), and 4 mmol L(-1) (P=0.39) were not significantly different from 40K(avgwatts).

Conclusion: We conclude that VT-based variables are generally superior to LT variables relative to predicting 40K(avgwatts), the simplest of several valid measures appears to be VE/VO2.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources

-